VARIABLE VOLUME AUTOSAMPLER


The Model 719AL autosampler is a syringe style, partial or full-loop injection autosampler that accepts 8mm, 12mm or 15mm vials or microplates. Three injection volume ranges are available by choosing a 50µL, 250µL or 2mL syringe. Designed for HPLC and LC/MS applications, the 719AL provides superior precision, accuracy, flexibility and reliability to your system.

BENEFITS

The Model 719AL autosampler is a syringe style, partial or full-loop injection autosampler that accepts 8mm, 12mm or 15mm vials or microplates. Three injection volume ranges are available by choosing a 50µL, 250µL or 2mL syringe. Designed for HPLC and LC/MS applications, the 719AL provides superior precision, accuracy, flexibility and reliability to your system. Emulating a manual HPLC injection process, the 719AL has zero sample loss and can reproducibly make 1µL injections from micro inserts containing as little as 3µL of total sample.


BENEFITS

> Accurate injection volumes from 0.06µL to 2mL using partial or full loop

> Internal and external needle rinse to eliminate carryover

> Optional vial trays available in three vial sizes plus microplates

> Automated dilutions, mixing, derivatizations and sample preparations

> Selectable needle depth

> Simple to use and maintain

> System interface through RS-232, IEEE, Contact Closures and I2C

> Customized software feature available


719AL Specifications

STANDARD

> Design Type: Variable Volume, XYZ movement, syringe loading

> Tray Capacities: 50 (15mm), 72 (12mm), or 128 (8mm) sample vials. Also, four 12 mm vials for standards or rinses

> Injections Per Vial: Unlimited Rinse Strokes 0-99 for needle port and needle

> Precision: Less than or equal to ±0.5% RSD, for 10µL partial loop injections under ACI test conditions

> Linearity: r2 <= 0.99

> Carryover: Less than 0.01% with rinse under ACI test conditions

> Sample Waste: None (or user selectable)

> Keypad: 20 key, 4 line, 80 character LCD

> Injection Parameters: Partial or fixed loop, sample draw speed, delay time, needle depth, pre-injection volume, pre/post-air volume, rinse strokes, rinse rate, pre pierce

> Syringe: 50, 250 (standard), or 2000 µL total volume

> Valve: Valco Cheminert C3 valve with 300µL loop and high speed actuator

> Programming: 10 Methods, maximum 128 steps per method. Priority sampling

> Communications: Interfaces: RS-232-C, IEEE, I2C

> Outputs:BCD, parallel printer port, inject market, 4 user selectable NO or NC Contact Closures with user selectable closure duration times.

> Dimensions: 33cm H x 32cm W x 55cm D (13" x 13" x 21")

> Weight: 14 Kg (31 lbs.) /17 Kg (38 lbs.) Refrigerated

> Wetted Materials: Teflon, 316 stainless steel and nitronic 60

> Voltage: Autoselectable: 100-240 VAC ±10%, 47-63 Hz

OPTIONS

> Syringe & Trays: 50µL and 2mL volumes 128 sample vials (8mm), will work with WISP vials 50 sample vials (15mm) Adapter for microplate trays

> Valves: C2 or C4 internal loop Cheminert Valves available

> Refrigeration: 4º C to 40º C within ±1° C accuracy using Peltier cooling of entire tray surface

> Other: Valveless models available for FIA and other direct injection applications